banner

Products

Portable Three Phase AC Voltage and Current Source

Portable Three Phase AC Voltage and Current Source

GF303D Portable Three Phase AC Voltage And Current Source It is suitable for power department, measuring department, qua
SHARE

Description

Basic Info
Model NO. GF303D
Customized Customized
Accuracy Class 0.05%, 0.1%
Power Supply Single Phase AC 85-265 V, Frequency 50/60 Hz
Weight (Kg) 27
Transport Package Standard Export Wooden Box
Specification 500x600x175
Trademark GFUVE
Origin Beijing, China
Production Capacity 1000pieces/Month
Product Description
GF303D Portable Three Phase AC Voltage And Current Source

It is suitable for power department, measuring department, quality control department, research units, and institutions of higher learning, and electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and the production of enterprise etc.
Features
To set up and take the load regulation of voltage, current, phase angle ,frequency and power factor etc; as a large current source, voltage source and power source
To set 2 ~ 31 times of the amplitude and phase harmonics, and it can be added to the base wave in every harmonic output
Voltage, current output a wide range, big power, high stability, waveform distortion degree is small
Strong with load ability, but it can take capacitive, sensibility, resistance of composite type load or load and load regulation is higher than 0.01%
To apply the 32 bit MPU + DSP + CPLD, powerful flexible
To use hardware PID, fast response, the change of load will not cause output volatility
Industrial frequency waves as high as 5000 points a week of the wave kneading, signal output without filter, precise output waveform, the harmonic output precision, harmonic distortion degree is small
Range switching automatically
To use software calibration, simple operation, stable and reliable
Display of vector diagram, adjustable to IEC387 OR DIN410
Big touch screen, 7-inch TFT color LCD display, English interface, operating simply
To have perfect over-current, over-voltage, heat, a shorts-and-opens, overload protection, failure detection automatically
With RS232 interface, and PC connection
To take place machine software, it can be output through the PC software program
Parameters
Electrical parameters
Accuracy class 0.05%, 0.1%
Power supplySingle phase AC 85-265 V, frequency 50/60 Hz
AC Voltage output
Range (U1, U2, U3 phase)57.7V/100V/220V/380V; range switch automatically(Max 500V)
Adjust fineness0.01% RG
Accuracy0.05% RG
Stability<0.01% RG/120s
Distortion degree<0.3% (not capacitive load)
Output power25VA
Full load regulation rate0.01% RG
Full load regulation timeLess than 1mS
Long-term stability± 60 PPM/year
AC Current output
Range (I1, I2, I3 phase)0.2A, 1A, 5A, 20A, 100A; range switch automatically
Adjustment range(0-120)%RG
Adjust fineness0.01% RG
Accuracy0.05% RG
Stability<0.01% RG/120s
Distortion degree<0.3% (not capacitive load)
Output power45VA
Full load regulation rate0.01% RG
Full load regulation timeLess than 1mS
Long-term stability± 60 PPM/year
Power output
Accuracy0.05% RG
Stability0.01% RG/120s
Phase angle
Adjusting range0°-359.99°
Resolution0.001°
Accuracy0.05°
Power factor
Adjusting range-1 ~ 0 ~ +1
Resolution0.0001
Accuracy0.0005
Frequency
Adjusting range40-65 Hz
Resolution0.001 Hz
Accuracy0.005 Hz
Temperature drift± 0.5 PPM/°C
Long-term stability± 4 PPM/year
Harmonic accuracy
Harmonic phase0°-359.99°
Harmonic phase accuracy< 0.01°
Harmonic set accuracy0.1% (relative to the base wave ratings)
Mechanical parameters
Dimensions (W×D×H) (mm)500x600x175
Weight (kg)27
Environmental conditions
Working temperature0°C to 40°C
Storage condition-30°C to -60°C
Relative humidity≤ 85%